PaperarXiv:2611.04185

What Does 4-Bit Microscaling Cost a Wearable Activity Recognizer? MXFP4 versus NVFP4 on Hang-Time HAR, Evaluated Player by Player

Preprint2026Added Nov 10, 2026

  • MH
  • HU

Authors: Megan Healy, Hossein Valavi (Princeton University)

arXiv preprint (cs.LG), v1 2026-11-03

TL;DR

Trains a 159,492-parameter 1D CNN to recognise four basketball actions from wrist accelerometer data (~50 Hz) in Hang-Time HAR (24 players), with five-fold cross-validation grouped by player so every test player is unseen. Compares number formats fold by fold: measured TFLite FP16 and INT8, and simulated 4-bit block-scaled MXFP4 (OCP) and NVFP4 (NVIDIA), for weights only and for weights plus activations, plus a 2 × 3 ablation of block size (16 vs 32) and scale rule.

  • Form factor: wrist

Abstract

Wearable sports sensors can recognize actions on the device itself, where lower-precision numbers reduce model storage and memory traffic. Two 4-bit block-scaled formats, MXFP4 from the Open Compute Project, introduced in 2023, and NVFP4 from NVIDIA, introduced in 2025, are drawing interest. Published evaluations cover general deep-learning benchmarks and large language models; to our knowledge, nobody has yet measured what they cost a small wearable-sensor model. We train a 159,492-parameter 1D CNN to recognize four basketball actions from wrist-accelerometer data in Hang-Time HAR and test it on players it has never seen, using five-fold cross-validation grouped by player. Every comparison between number formats is made fold by fold. In full precision the model reaches 69.26% macro-F1. Measured TFLite FP16 and INT8 models lose at most 0.16 percentage points. In simulation, 4-bit weights cost 1.45 points with MXFP4 and 0.72 points with NVFP4. When activations are quantized to 4 bits as well, MXFP4 loses 5.14 points and NVFP4 only 0.75, and NVFP4 comes out ahead in all five held-out-player folds. The ranking survives two alternative simulator settings, with NVFP4 leading by 3.49 to 4.40 points. A 2 × 3 ablation with 4-bit weights and activations (two block sizes and three scale rules) points to scale selection as the main source of MXFP4's loss. The reference MXFP4 conversion we simulate rounds the scale down, which can pick scales that are too small, so many blocks clip their largest values. Rounding the scale up recovers 3.18 points with 32-value blocks and 3.63 points with 16-value blocks, and switching to an 8-bit floating-point scale, as NVFP4 does, adds another 0.84 and 1.20 points. Block size matters less. Under this round-down rule, 16-value blocks score 0.44 points below 32-value blocks in all five folds; under the other two rules there is no consistent effect.

Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Activity recognition

Signals

Keywords

HarQuantizationMxfp4Nvfp4Int8Fp16TfliteMicroscaling

How it works

How Method works: Setup → Method → TargetSetup: Signals (accel); Form factor (wrist). Method: Method. Target: Activity recognition.SetupSignals: accelxyzSignalsaccelForm factor: wristForm factorwristMethodMethodTargetActivity recognitionActivity recognition

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Healy, M., & Valavi, H. (2026). What Does 4-Bit Microscaling Cost a Wearable Activity Recognizer? MXFP4 versus NVFP4 on Hang-Time HAR, Evaluated Player by Player. arXiv preprint , v1. https://arxiv.org/abs/2611.04185
Healy, Megan and Hossein Valavi. 2026. "What Does 4-Bit Microscaling Cost a Wearable Activity Recognizer? MXFP4 versus NVFP4 on Hang-Time HAR, Evaluated Player by Player." arXiv preprint , v1. https://arxiv.org/abs/2611.04185.
Healy, M. and Valavi, H. (2026) 'What Does 4-Bit Microscaling Cost a Wearable Activity Recognizer? MXFP4 versus NVFP4 on Hang-Time HAR, Evaluated Player by Player', arXiv preprint , v1. Available at: https://arxiv.org/abs/2611.04185
Healy, Megan, and Hossein Valavi "What Does 4-Bit Microscaling Cost a Wearable Activity Recognizer? MXFP4 versus NVFP4 on Hang-Time HAR, Evaluated Player by Player." arXiv preprint , v1, 2026. https://arxiv.org/abs/2611.04185.
M. Healy and H. Valavi, "What Does 4-Bit Microscaling Cost a Wearable Activity Recognizer? MXFP4 versus NVFP4 on Hang-Time HAR, Evaluated Player by Player," arXiv preprint , v1, 2026, [Online]. Available: https://arxiv.org/abs/2611.04185.
@misc{healy2026what,
  title         = {{What Does 4-Bit Microscaling Cost a Wearable Activity Recognizer? MXFP4 versus NVFP4 on Hang-Time HAR, Evaluated Player by Player}},
  author        = {Healy, Megan and Valavi, Hossein},
  year          = {2026},
  howpublished  = {arXiv preprint , v1},
  eprint        = {2611.04185},
  archivePrefix = {arXiv}
}

Source metadata: 2026

Record updated Nov 10, 2026

Added to the ChatPPG research hub