Paperdoi:10.1088/1742-6596/1151/1/012005
Monte Carlo model for reflectance Pulse Oximetry using pulsatile monolayer perfused skin tissue
Journal of Physics: Conference Series
TL;DR
Pulse Oximetry (PO) is a non-invasive method for estimating arterial oxygen saturation from Photoplethysmography signals recorded from peripheral tissue sites. Despite a very wide range of clinical applications, the fundamental working principles of PO is still not very well understood. In this work, a Monte Carlo model is executed for a monolayer volume of human skin dermis in a reflectance detection modality to investigate the basic nature of light-tissue interaction in the tissue.
Abstract
Pulse Oximetry (PO) is a non-invasive method for estimating arterial oxygen saturation from Photoplethysmography signals recorded from peripheral tissue sites. Despite a very wide range of clinical applications, the fundamental working principles of PO is still not very well understood. In this work, a Monte Carlo model is executed for a monolayer volume of human skin dermis in a reflectance detection modality to investigate the basic nature of light-tissue interaction in the tissue. Differences in systolic and diastolic blood volume explained the pulsatility. The distribution of light-tissue interaction was illustrated, systolic and diastolic reflectance at red and infrared light were simulated and the ‘calibration curve’ was produced
Verbatim from Semantic Scholar (opens in a new tab) · Abstract via Semantic Scholar; © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
Chatterjee, S., & Kyriacou, P. A. (2019). Monte Carlo model for reflectance Pulse Oximetry using pulsatile monolayer perfused skin tissue. Journal of Physics: Conference Series. https://doi.org/10.1088/1742-6596/1151/1/012005
Chatterjee, S and P A Kyriacou. 2019. "Monte Carlo model for reflectance Pulse Oximetry using pulsatile monolayer perfused skin tissue." Journal of Physics: Conference Series. https://doi.org/10.1088/1742-6596/1151/1/012005.
Chatterjee, S. and Kyriacou, P. A. (2019) 'Monte Carlo model for reflectance Pulse Oximetry using pulsatile monolayer perfused skin tissue', Journal of Physics: Conference Series. doi: 10.1088/1742-6596/1151/1/012005.
Chatterjee, S, and P A Kyriacou "Monte Carlo model for reflectance Pulse Oximetry using pulsatile monolayer perfused skin tissue." Journal of Physics: Conference Series, 2019. https://doi.org/10.1088/1742-6596/1151/1/012005.
S. Chatterjee and P. A. Kyriacou, "Monte Carlo model for reflectance Pulse Oximetry using pulsatile monolayer perfused skin tissue," Journal of Physics: Conference Series, 2019, doi: 10.1088/1742-6596/1151/1/012005.
@inproceedings{chatterjee2019monte,
title = {{Monte Carlo model for reflectance Pulse Oximetry using pulsatile monolayer perfused skin tissue}},
author = {Chatterjee, S. and Kyriacou, P. A.},
year = {2019},
booktitle = {Journal of Physics: Conference Series},
doi = {10.1088/1742-6596/1151/1/012005}
}Added to the ChatPPG research hub