Foundation model

CardioLoom (report-guided ECG foundation model)

PreprintCatalog paper date: Nov 18, 2026Added to atlas: Nov 19, 2026Source

Activity counts measure attention, not model quality. Missing counts are unknown. Publication status follows the linked source; a listed venue alone does not confirm peer review.

Report-guided 12-lead ECG FM; macro-AUPRC 0.624 vs 0.615 (DeepECG-SSL) on 45 internal diagnoses, ties externally, strong label efficiency. Paper: the CardioLoom paper.

Signals
ECG, Text
License
MIT (code)
Year
2026
Architecture

ECG encoder initialised from DeepECG-SSL trained against MedCPT report embeddings; report-shared positives

Pretraining data

2,781,289 ECG-report pairs, 1,298,359 patients (Zhongshan; not released)

At a glance
Type
Foundation model
Modalities
ECGText
Form factor
Not reported
Parameters
Not reported
Architecture
ECG encoder initialised from DeepECG-SSL trained against MedCPT report embeddings; report-shared positives
Venue
Not reported
Year
2026
DOI
Not reported
Weights
Not released
Caveats
Not reported
Datasets
Not reported
Added
Nov 19, 2026
Updated
Nov 19, 2026

Abstract

Routine electrocardiogram (ECG) reports offer scalable supervision for cardiovascular representation learning. In this retrospective study, we pretrained CardioLoom, a report-guided ECG foundation model, on 2,781,289 ECG-report pairs from 1,298,359 patients. Downstream development used a separate cohort of 721,317 ECGs from 233,798 patients. Evaluation covered 89 targets, with external testing in nine cohorts. Across 45 internal ECG diagnoses, macro area under the precision-recall curve (AUPRC) was 0.624 versus 0.615 for DeepECG-SSL. Across 203 external ECG evaluations, corresponding means were 0.425 and 0.424. Using labels from 10% of training patients, CardioLoom achieved macro-AUPRC 0.559, exceeding supervised training with all labels (0.549). For heart failure with reduced ejection fraction, AUPRCs were 0.690, 0.641 and 0.677 in Zhongshan, Shiyuan and BIDMC. Cardiac amyloidosis screening yielded 4.5% positive predictive value using a threshold targeting 99% specificity in validation. Report-guided pretraining supported label-efficient ECG diagnosis, with variable transfer across echocardiographic phenotypes.

Verbatim fromarXiv· arXiv metadata (abstracts are released under CC0)

CardioLoom (report-guided ECG foundation model): ChatPPG research summary card

Key results

0.624
AUPRC
macro-AUPRC 0.624 vs 0.615 (DeepECG-SSL) on 45 internal diagnoses, ties externally, strong label efficiency

How it works

How CardioLoom (report-guided ECG foundation model) works: Input signals → Foundation model → Downstream tasksInput signals: ECG (Electrocardiogram); Text (Language). Pretraining data: 2,781,289 ECG-report pairs, 1,298,359 patients (Zhongshan; not released). Foundation model: CardioLoom (report-guided ECG foundation model).Input signalsECG: ElectrocardiogramECGElectrocardiogramText: LanguageTextLanguagePretraining data: 2,781,289 ECG-report pairs, 1,298,359 patients (Zhongshan; not released)Pretraining data2,781,289 ECG-report pairsFoundation modelCardioLoom (report-guided ECG…
Pretraining data
2,781,289 ECG-report pairs, 1,298,359 patients (Zhongshan; not released)
Architecture
ECG encoder initialised from DeepECG-SSL trained against MedCPT report embeddings; report-shared positives
Inputs
ECG, Text
Approach
ecg fm · report guided · label efficient · no weights

Datasets used

No public datasets linked yet.

Papers· 1

Cite this model

Cite the publication recorded for this model. Check it against the publisher before submitting.

Yu, Z., Tao, Y., Huo, J., et al. (2026). CardioLoom: A Report-Guided Electrocardiogram Foundation Model for Cross-Domain Cardiovascular Phenotyping. arXiv:2605.25446. https://arxiv.org/abs/2605.25446
Yu, Ziqing, Yuhui Tao, and Jiayu Huo, et al. 2026. "CardioLoom: A Report-Guided Electrocardiogram Foundation Model for Cross-Domain Cardiovascular Phenotyping." arXiv:2605.25446. https://arxiv.org/abs/2605.25446.
Yu, Z., Tao, Y. and Huo, J. et al. (2026) 'CardioLoom: A Report-Guided Electrocardiogram Foundation Model for Cross-Domain Cardiovascular Phenotyping', arXiv:2605.25446. Available at: https://arxiv.org/abs/2605.25446
Yu, Ziqing, et al. "CardioLoom: A Report-Guided Electrocardiogram Foundation Model for Cross-Domain Cardiovascular Phenotyping." arXiv:2605.25446, 2026. https://arxiv.org/abs/2605.25446.
Z. Yu et al., "CardioLoom: A Report-Guided Electrocardiogram Foundation Model for Cross-Domain Cardiovascular Phenotyping," arXiv:2605.25446, 2026, [Online]. Available: https://arxiv.org/abs/2605.25446.
@misc{yu2026cardioloom,
  title         = {{CardioLoom: A Report-Guided Electrocardiogram Foundation Model for Cross-Domain Cardiovascular Phenotyping}},
  author        = {Yu, Ziqing and Tao, Yuhui and Huo, Jiayu and others},
  year          = {2026},
  howpublished  = {arXiv:2605.25446},
  eprint        = {2605.25446},
  archivePrefix = {arXiv}
}

Source metadata: 2026

Record updated Nov 19, 2026

History

  1. Added to the ChatPPG research hub