K232053: SimpleSense-BP, SimpleSense-BP Software Application (Nanowear, Inc.)

Nanowear, Inc. received FDA 510(k) K232053 for SimpleSense-BP, SimpleSense-BP Software Application, with a decision date of Dec 8, 2023 (substantially equivalent).

Prescription or OTC: Unknown (no FDA document we parsed states it).

FDA record for K232053FDA summary or statement (PDF)

FDA facts

Official fields for K232053
FDA numberK232053
Pathway510(k)
ApplicantNanowear, Inc.
Device nameSimpleSense-BP, SimpleSense-BP Software Application
Product codeDXN: System, Measurement, Blood-Pressure, Non-Invasive
Regulation (21 CFR)870.1130
Device classClass 2
Date receivedJul 11, 2023
Decision dateDec 8, 2023
DecisionSubstantially Equivalent (SESE)
510(k) typeTraditional

Source: openFDA device 510(k) data, data through Oct 26, 2026.

Indications for use parsed from FDA documents

The SimpleSense Platform is intended for use at home, a healthcare facility, or medical research organization under the direction of a licensed medical professional to record, display, and store the following physiological data: a) 2 leads of Electrocardiogram; b) Respiration rate measured through thoracic impedance; c) Heart Sounds; d) Activity including posture; e) Systolic and Diastolic Blood Pressure and f) other validated data sources. The SimpleSense Platform is intended for use when the licensed medical professional decides to evaluate the physiologic signals of adult patients as an aid to diagnosis and treatment. The SimpleSense Platform is intended to be used by patients at rest with a stationary torso. ECG recordings are indicated for the manual assessment of cardiac rhythm disturbances. The SimpleSense Platform does not produce alarms and is not intended for active patient monitoring. The SimpleSense Platform is not intended for use as life supporting equipment on high-risk patients such as critical care patients. The SimpleSense Platform is not intended for use in the presence of a pacemaker. The SimpleSense-BP software application is intended to estimate, display and store blood pressure data on adult patients who are twenty two (22) years and older. The SimpleSense-BP can be used after a clinician determines the user’s hypertension classification via an auscultatory blood pressure cuff measurement. The Blood Pressure algorithm uses patient specific information (age, gender, height and weight) and the blood pressure measurement as inputs. SimpleSense-BP is used to provide blood pressure estimations derived from physiological sensors to qualified medical personnel as a complimentary physiological feature for the purposes of assessing a patient’s cardiac heal

Extracted automatically from FDA's 510(k) summary. It can contain extraction errors and is not a verified quote. Read the wording in the FDA PDF before relying on it.

Predicates parsed from FDA documents

FDA numbers found next to the word "predicate" in the summary. The list can include reference devices; check the PDF for which device is the primary predicate.

ChatPPG interpretation

A 510(k) decision of "substantially equivalent" means FDA found the device as safe and effective as a legally marketed predicate. FDA's word for this is cleared, not approved. The clearance covers the device and indications in this submission; it does not extend to other features or versions of the same product that were not part of it. See FDA cleared vs approved.

Product code DXN is "System, Measurement, Blood-Pressure, Non-Invasive", class 2, 21 CFR 870.1130.

Our labels for filtering: claim Blood pressure, sensor Cuff. These are heuristics, not FDA fields.