FDA 510(k) · Nanowear

K201669: SimpleSENSE (Nanowear, Inc.)

Nanowear, Inc. received FDA 510(k) K201669 for SimpleSENSE, with a decision date of Nov 6, 2020 (substantially equivalent).

Prescription or OTC: Unknown (no FDA document we parsed states it).

FDA record for K201669FDA summary or statement (PDF)

FDA facts

Official fields for K201669
FDA numberK201669
Pathway510(k)
ApplicantNanowear, Inc.
Device nameSimpleSENSE
Product codeDXH: Transmitters And Receivers, Electrocardiograph, Telephone
Regulation (21 CFR)870.2920
Device classClass 2
Date receivedJun 19, 2020
Decision dateNov 6, 2020
DecisionSubstantially Equivalent (SESE)
510(k) typeTraditional

Source: openFDA device 510(k) data, data through Oct 26, 2026.

Indications for use parsed from FDA documents

The SimpleSENSE System is intended for use at home, or at a healthcare facility, under the direction of a licensed medical professional, to record, display and store the following physiological data: a) 2 leads of Electrocardiogram; b) Respiration rate measured through thoracic impedance; c) Heart Sounds; and d) Activity including posture. The device is intended for use when the clinician decides to evaluate the physiologic signals of adult patients as an aid to diagnosis and treatment. The SimpleSENSE System is intended to be used by patients at rest and not performing any activities or movements. ECG recordings are indicated for the manual assessment of cardiac rhythm disturbances. The device does not produce alarms and is not intended for active patient monitoring (real-time). The device is not intended for use as life supporting equipment on high-risk patients such as critical care patients. The device is not intended for use in the presence of a pacemaker.

Extracted automatically from FDA's 510(k) summary. It can contain extraction errors and is not a verified quote. Read the wording in the FDA PDF before relying on it.

Predicates parsed from FDA documents

FDA numbers found next to the word "predicate" in the summary. The list can include reference devices; check the PDF for which device is the primary predicate.

Later records that cite K201669

  • K212160 SimpleSENSE Platform (Nanowear, Sep 22, 2021, DXH)

ChatPPG interpretation

A 510(k) decision of "substantially equivalent" means FDA found the device as safe and effective as a legally marketed predicate. FDA's word for this is cleared, not approved. The clearance covers the device and indications in this submission; it does not extend to other features or versions of the same product that were not part of it. See FDA cleared vs approved.

Product code DXH is "Transmitters And Receivers, Electrocardiograph, Telephone", class 2, 21 CFR 870.2920.

Our labels for filtering: claim ECG, sensor ECG electrodes. These are heuristics, not FDA fields.