Paperdoi:10.1109/iembs.2011.6090995

Development of a reflectance photoplethysmographic sensor used for the assessment of free flap perfusion

Venue listed2011Added Nov 5, 2026

  • TZ
  • PK
  • SP

Authors: T. Zaman, P. A. Kyriacou, S. K. Pal

2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society

TL;DR

Monitoring of free flap perfusion and early identification of flap failure is an indispensable prerequisite for flap salvage. Although many methods of free flap monitoring are available, there is still no single reliable continuous non-invasive perfusion monitoring technique which will also assist in the early recognition of flap failure. The new prototype reflectance photoplethysmographic sensor was evaluated on three anaesthetized patients undergoing elective breast reconstructive (Deep Inferior Epigastric Perforator Flap) surgery.

  • Published in 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (2011).

Abstract

Monitoring of free flap perfusion and early identification of flap failure is an indispensable prerequisite for flap salvage. Although many methods of free flap monitoring are available, there is still no single reliable continuous non-invasive perfusion monitoring technique which will also assist in the early recognition of flap failure. In order to overcome the current technological limitations, we have developed a multi-wavelength photoplethysmographic (PPG) sensor and processing system to systematically investigate the perfusion mechanism in flaps used in reconstructive plastic microsurgery. The new prototype reflectance photoplethysmographic sensor was evaluated on three anaesthetized patients undergoing elective breast reconstructive (Deep Inferior Epigastric Perforator Flap) surgery. PPG signals were successfully obtained pre-operatively, intra-operatively and post-operatively. These preliminary results suggest that a PPG sensor may be a suitable method for evaluating the perfusion of free flap.

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Kyriacou BibliographyOrgan Tissue Perfusion

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG). Method: Method.SetupSignals: PPGSignalsPPGMethodMethod

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Zaman, T., Kyriacou, P. A., & Pal, S. K. (2011). Development of a reflectance photoplethysmographic sensor used for the assessment of free flap perfusion. 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2011.6090995
Zaman, T., P. A. Kyriacou, and S. K. Pal. 2011. "Development of a reflectance photoplethysmographic sensor used for the assessment of free flap perfusion." 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2011.6090995.
Zaman, T., Kyriacou, P. A. and Pal, S. K. (2011) 'Development of a reflectance photoplethysmographic sensor used for the assessment of free flap perfusion', 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. doi: 10.1109/iembs.2011.6090995.
Zaman, T., et al. "Development of a reflectance photoplethysmographic sensor used for the assessment of free flap perfusion." 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011. https://doi.org/10.1109/iembs.2011.6090995.
T. Zaman, P. A. Kyriacou, and S. K. Pal, "Development of a reflectance photoplethysmographic sensor used for the assessment of free flap perfusion," 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011, doi: 10.1109/iembs.2011.6090995.
@inproceedings{zaman2011development,
  title         = {{Development of a reflectance photoplethysmographic sensor used for the assessment of free flap perfusion}},
  author        = {Zaman, T. and Kyriacou, P. A. and Pal, S. K.},
  year          = {2011},
  booktitle     = {2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society},
  doi           = {10.1109/iembs.2011.6090995}
}

Added to the ChatPPG research hub