Paperdoi:10.1109/embc.2017.8037204

Development of an intraluminal intestinal photoplethysmography sensor

Venue listed2017Added Nov 5, 2026

  • ZP
  • MT
  • PK

Authors: Zaibaa Patel, Mohamed A. Thaha, Panayiotis A. Kyriacou

2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)

TL;DR

Intestinal ischemia is a serious medical condition and can lead to life threatening sepsis. Currently, there are no reliable techniques available for directly monitoring intestinal viability for prolonged periods of time, and intraoperatively, the majority of the surgeons still rely on subjective methods, such as visual inspection to assess viability of the intestine. The development of an intraluminal optical sensor for monitoring intestinal viability is being proposed.

  • Published in 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (2017).

Abstract

Intestinal ischemia is a serious medical condition and can lead to life threatening sepsis. Currently, there are no reliable techniques available for directly monitoring intestinal viability for prolonged periods of time, and intraoperatively, the majority of the surgeons still rely on subjective methods, such as visual inspection to assess viability of the intestine. The development of an intraluminal optical sensor for monitoring intestinal viability is being proposed. The sensor will continuously monitor changes in blood volume and oxygen saturation. The developed reflectance photoplethysmography/pulse oximetry sensor comprises of two emitters (red and infrared) and a photodiode. A photoplethysmography processing and data acquisition system was also utilized. The prototype sensor was evaluated in a pilot study in the buccal mucosa of 12 healthy volunteers, given the locations similarity to the intestinal mucosa and its easy accessibility. Good quality photoplethysmography signals with high signal-to-noise ratio were acquired from the buccal mucosa in all the volunteers. Preliminary blood oxygen saturation values from the intraluminal sensor were in broad agreement with the standard finger pulse oximeter probes.

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Kyriacou BibliographyOrgan Tissue Perfusion

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG). Method: Method.SetupSignals: PPGSignalsPPGMethodMethod

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Patel, Z., Thaha, M. A., & Kyriacou, P. A. (2017). Development of an intraluminal intestinal photoplethysmography sensor. 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2017.8037204
Patel, Zaibaa, Mohamed A. Thaha, and Panayiotis A. Kyriacou. 2017. "Development of an intraluminal intestinal photoplethysmography sensor." 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2017.8037204.
Patel, Z., Thaha, M. A. and Kyriacou, P. A. (2017) 'Development of an intraluminal intestinal photoplethysmography sensor', 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. doi: 10.1109/embc.2017.8037204.
Patel, Zaibaa, et al. "Development of an intraluminal intestinal photoplethysmography sensor." 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2017. https://doi.org/10.1109/embc.2017.8037204.
Z. Patel, M. A. Thaha, and P. A. Kyriacou, "Development of an intraluminal intestinal photoplethysmography sensor," 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2017, doi: 10.1109/embc.2017.8037204.
@inproceedings{patel2017development,
  title         = {{Development of an intraluminal intestinal photoplethysmography sensor}},
  author        = {Patel, Zaibaa and Thaha, Mohamed A. and Kyriacou, Panayiotis A.},
  year          = {2017},
  booktitle     = {2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society},
  doi           = {10.1109/embc.2017.8037204}
}

Added to the ChatPPG research hub