PaperarXiv:2602.12478

Task- and Metric-Specific Signal Quality Indices for Medical Time Series

Preprint2026Added Sep 26, 2026

  • JH
  • CA

Authors: Jad Haidamous, Christoph Hoog Antink

arXiv preprint (eess.SP, cs.LG) · 5 pages, 3 figures, submitted to EUSIPCO 2026

Open code

First page or project page of “Task- and Metric-Specific Signal Quality Indices for Medical Time Series” (opens in a new tab)

Haidamous, Jad et al., "Task- and Metric-Specific Signal Quality Indices for Medical Time Series", arXiv:2602.12478, CC BY 4.0

TL;DR

Medical time series such as electrocardiograms (ECGs) and photoplethysmograms (PPGs) are frequently affected by measurement artifacts due to challenging acquisition environments, such as in ambulances and during routine daily activities. Since automated algorithms for analyzing such signals increasingly inform clinically relevant decisions, identifying signal segments on which these algorithms may produce unreliable outputs is of critical importance. Signal quality indices (SQIs) are commonly used for this purpose.

  • Form factor: other

Abstract

Medical time series such as electrocardiograms (ECGs) and photoplethysmograms (PPGs) are frequently affected by measurement artifacts due to challenging acquisition environments, such as in ambulances and during routine daily activities. Since automated algorithms for analyzing such signals increasingly inform clinically relevant decisions, identifying signal segments on which these algorithms may produce unreliable outputs is of critical importance. Signal quality indices (SQIs) are commonly used for this purpose. However, most existing SQIs are task agnostic and do not account for the specific algorithm and performance metric used downstream. In this work, we formalize signal quality as a task- and metric-dependent concept and propose a perturbation-based SQI (pSQI) that aims to detect an algorithm's performance degradation on an input signal with respect to a metric. The pSQI is defined as the worst-case value of the performance metric under an additive, colored Gaussian noise perturbation with a lower-bounded signal-to-noise ratio. We introduce formal requirements for task- and metric-specific SQIs, including monotonicity of the metric in expectation and maximal separation under thresholding. Experiments on R-peak detection and atrial fibrillation classification benchmarks demonstrate that the proposed pSQI consistently outperforms existing feature- and deep learning-based SQIs in identifying unreliable inputs without requiring training.

Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Signal quality

Signals

Keywords

SQItask-specificperturbationopen-code

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG, ECG); Form factor (other). Method: Method. Target: Signal quality.SetupSignals: PPG, ECGSignalsPPG, ECGForm factor: otherForm factorotherMethodMethodTargetSignal qualitySignal quality

Cite this paper

APA

Haidamous, J., & Antink, C. H. (2026). Task- and Metric-Specific Signal Quality Indices for Medical Time Series. arXiv preprint · 5 pages, 3 figures, submitted to EUSIPCO 2026. https://doi.org/10.48550/arXiv.2602.12478

BibTeX

@misc{haidamous2026task,
  title         = {{Task- and Metric-Specific Signal Quality Indices for Medical Time Series}},
  author        = {Haidamous, Jad and Antink, Christoph Hoog},
  year          = {2026},
  howpublished  = {arXiv preprint · 5 pages, 3 figures, submitted to EUSIPCO 2026},
  doi           = {10.48550/arXiv.2602.12478},
  eprint        = {2602.12478},
  archivePrefix = {arXiv}
}

Built from the hub record. Check it against the publisher before submitting.

Record updated

Added to the ChatPPG research hub