Paperdoi:10.1016/j.measurement.2009.03.004

Measurement of photoplethysmographic signals in human abdominal organs

Venue listed2009Added Nov 5, 2026

  • PK
  • AG
  • RL
  • DJ

Authors: P.A. Kyriacou, A. Crerar-Gilbert, R.M. Langford, D.P. Jones

Measurement

TL;DR

There is a need for reliable continuous monitoring of abdominal organ oxygen saturation (SpO2). Splanchnic ischaemia may ultimately lead to cellular hypoxia and necrosis and contribute to the development of multiple organ failure and increased mortality. A reflectance electro-optical photoplethysmographic (PPG) probe and signal processing system were developed.

  • Published in Measurement (2009).

Abstract

There is a need for reliable continuous monitoring of abdominal organ oxygen saturation (SpO2). Splanchnic ischaemia may ultimately lead to cellular hypoxia and necrosis and contribute to the development of multiple organ failure and increased mortality. A reflectance electro-optical photoplethysmographic (PPG) probe and signal processing system were developed. Satisfactory PPG signals from abdominal organs (bowel, liver and kidney) and the finger were obtained from 12 anaesthetised patients. There were no statistically significant differences between the average PPG amplitudes recorded from the abdominal organs and those obtained simultaneously from the finger. These observations suggest that pulse oximetry can be a valid monitoring technique for abdominal organs such as the bowel, liver and kidney.

Verbatim from Semantic Scholar (opens in a new tab) · Abstract via Semantic Scholar; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Kyriacou BibliographyOrgan Tissue Perfusion

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG). Method: Method.SetupSignals: PPGSignalsPPGMethodMethod

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Kyriacou, P., Crerar-Gilbert, A., Langford, R., & Jones, D. (2009). Measurement of photoplethysmographic signals in human abdominal organs. Measurement. https://doi.org/10.1016/j.measurement.2009.03.004
Kyriacou, P.A., A. Crerar-Gilbert, R.M. Langford, and D.P. Jones. 2009. "Measurement of photoplethysmographic signals in human abdominal organs." Measurement. https://doi.org/10.1016/j.measurement.2009.03.004.
Kyriacou, P., Crerar-Gilbert, A., Langford, R. and Jones, D. (2009) 'Measurement of photoplethysmographic signals in human abdominal organs', Measurement. doi: 10.1016/j.measurement.2009.03.004.
Kyriacou, P.A., et al. "Measurement of photoplethysmographic signals in human abdominal organs." Measurement, 2009. https://doi.org/10.1016/j.measurement.2009.03.004.
P. Kyriacou, A. Crerar-Gilbert, R. Langford, and D. Jones, "Measurement of photoplethysmographic signals in human abdominal organs," Measurement, 2009, doi: 10.1016/j.measurement.2009.03.004.
@article{kyriacou2009measurement,
  title         = {{Measurement of photoplethysmographic signals in human abdominal organs}},
  author        = {Kyriacou, P.A. and Crerar-Gilbert, A. and Langford, R.M. and Jones, D.P.},
  year          = {2009},
  journal       = {Measurement},
  doi           = {10.1016/j.measurement.2009.03.004}
}