TL;DR

Reviews single-site PPG BP estimation from 2010 to 2019. It covers which PPG features relate to BP and how studies handled validation, sample size, subject diversity and datasets, and it sets out the challenges for wearable deployment.

  • Form factor: mixed (single-site)

Abstract

One in three adults worldwide has hypertension, which is associated with significant morbidity and mortality. Consequently, there is a global demand for continuous and non-invasive blood pressure (BP) measurements that are convenient, easy to use, and more accurate than the currently available methods for detecting hypertension. This could easily be achieved through the integration of single-site photoplethysmography (PPG) readings into wearable devices, although improved reliability and an understanding of BP estimation accuracy are essential. This review paper focuses on understanding the features of PPG associated with BP and examines the development of this technology over the 2010–2019 period in terms of validation, sample size, diversity of subjects, and datasets used. Challenges and opportunities to move single-site PPG forward are also discussed.

Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://creativecommons.org/licenses/by/4.0/

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Blood pressure

Signals

Keywords

ReviewCuffless BPSingle SiteValidation

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG); Form factor (mixed (single-site)). Method: Method. Target: Blood pressure.SetupSignals: PPGSignalsPPGForm factor: mixed (single-site)Form factormixed (single-site)MethodMethodTargetBlood pressureBlood pressure

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Hosanee, M., Chan, G., Welykholowa, K., Cooper, R. E., Kyriacou, P. A., Zheng, D., Allen, J., Abbott, D., Menon, C., Lovell, N. H., et al. (2020). Cuffless single-site photoplethysmography for blood pressure monitoring. J. Clin. Med. 2020, 9, 723. https://doi.org/10.3390/jcm9030723
Hosanee, Manish, Gabriel Chan, Kaylie Welykholowa, Rachel E. Cooper, P. A. Kyriacou, Dingchang Zheng, John Allen, Derek Abbott, Carlo Menon, and Nigel Hamilton Lovell, et al. 2020. "Cuffless single-site photoplethysmography for blood pressure monitoring." J. Clin. Med. 2020 9: 723. https://doi.org/10.3390/jcm9030723.
Hosanee, M., Chan, G., Welykholowa, K., Cooper, R. E., Kyriacou, P. A., Zheng, D., Allen, J., Abbott, D., Menon, C. and Lovell, N. H. et al. (2020) 'Cuffless single-site photoplethysmography for blood pressure monitoring', J. Clin. Med. 2020, 9, p. 723. doi: 10.3390/jcm9030723.
Hosanee, Manish, et al. "Cuffless single-site photoplethysmography for blood pressure monitoring." J. Clin. Med. 2020, vol. 9, 2020, p. 723. https://doi.org/10.3390/jcm9030723.
M. Hosanee et al., "Cuffless single-site photoplethysmography for blood pressure monitoring," J. Clin. Med. 2020, vol. 9, p. 723, 2020, doi: 10.3390/jcm9030723.
@article{hosanee2020cuffless,
  title         = {{Cuffless single-site photoplethysmography for blood pressure monitoring}},
  author        = {Hosanee, Manish and Chan, Gabriel and Welykholowa, Kaylie and Cooper, Rachel E. and Kyriacou, P. A. and Zheng, Dingchang and Allen, John and Abbott, Derek and Menon, Carlo and Lovell, Nigel Hamilton and others},
  year          = {2020},
  journal       = {J. Clin. Med. 2020},
  volume        = {9},
  pages         = {723},
  doi           = {10.3390/jcm9030723}
}

Added to the ChatPPG research hub