PaperarXiv:2611.00011
ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals
arXiv 2611.00011 (dated 2026-09-15); under review
Soumma, Shovito Barua et al., "ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals", arXiv:2611.00011, CC BY 4.0
TL;DR
ARTA (Artifact-Robust Temporal Alignment) pools beat candidates from several ECG QRS detectors into a directed acyclic graph, links them by physiologically plausible RR intervals, scores nodes by detector agreement and local ECG quality, and adds history-dependent transition costs plus a soft HR prior. Beam-search dynamic programming picks one coherent beat path, suppressing false peaks and recovering missed beats. On the IEEE Signal Processing Cup exercise data with electrode-motion noise (-2 to 12 dB): HR MAE 1.79 bpm (54% below the best single detector), 92.38% of windows within ±5 bpm, R-peak F1 0.95, IBI MAE 6.52 ms.
- Form factor: wearable-ecg
Abstract
Accurate heart rate (HR) and interbeat interval (IBI) estimation from wearable electrocardiogram (ECG) is essential for continuous physiological monitoring, but motion artifacts can create false QRS-like peaks and obscure true R-peaks. Conventional detectors and local interval-repair rules process detections independently and may become unreliable when several consecutive beats are corrupted. We present ARTA (Artifact-Robust Temporal Alignment), a graph-based combinatorial framework that estimates the heartbeat sequence through constrained temporal optimization. ARTA combines candidates from multiple ECG detectors, represents them as nodes in a directed acyclic graph and connects candidates through physiologically plausible RR intervals. Candidate confidence uses detector agreement and local ECG quality, while history-dependent transition costs capture recent IBI consistency and a soft heart-rate prior. Beam-search dynamic programming selects a coherent low-cost path across the recording, suppressing false detections and recovering missed beats when plausible auxiliary candidates are available. On the IEEE Signal Processing Cup exercise dataset with electrode-motion artifacts from -2 to 12 dB, ARTA achieved an HR mean absolute error of 1.79 beats per minute, 54% lower than the strongest single-detector baseline, with 92.38% of windows within +/-5 beats per minute, an R-peak F1 score of 0.95, and an IBI mean absolute error of 6.52 ms. Cross-dataset evaluation on the European ST-T Database further assessed transfer to long clinical ambulatory recordings and a label-free reliability analysis examined conditional performance without using reference annotations for segment selection. ARTA is single-channel, training-free, interpretable and computationally lightweight, operating approximately 27 times faster than real time with peak memory below 2.1 MB in a single-thread CPU simulation.
Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
Datasets used
How it works
Cite this paper
Soumma, S. B., Arefeen, A., & Ghasemzadeh, H. (2026). ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals. arXiv 2611.00011. https://arxiv.org/abs/2611.00011
Soumma, Shovito Barua, Asiful Arefeen, and Hassan Ghasemzadeh. 2026. "ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals." arXiv 2611.00011. https://arxiv.org/abs/2611.00011.
Soumma, S. B., Arefeen, A. and Ghasemzadeh, H. (2026) 'ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals', arXiv 2611.00011. Available at: https://arxiv.org/abs/2611.00011
Soumma, Shovito Barua, et al. "ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals." arXiv 2611.00011, 2026. https://arxiv.org/abs/2611.00011.
S. B. Soumma, A. Arefeen, and H. Ghasemzadeh, "ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals," arXiv 2611.00011, 2026, [Online]. Available: https://arxiv.org/abs/2611.00011.
@misc{soumma2026arta,
title = {{ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals}},
author = {Soumma, Shovito Barua and Arefeen, Asiful and Ghasemzadeh, Hassan},
year = {2026},
howpublished = {arXiv 2611.00011},
eprint = {2611.00011},
archivePrefix = {arXiv}
}Added to the ChatPPG research hub