Paperdoi:10.1109/iembs.2009.5334165

A novel non-invasive trans-reflectance photoplethysmographic probe for use in cases of low peripheral blood perfusion

Venue listed2009Added Nov 5, 2026

  • MS
  • JP
  • PK

Authors: M. Shafique, J.P. Phillips, P.A. Kyriacou

2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society

TL;DR

The acquisition of reliable and meaningful photo-plethysmographic (PPG) signals using conventional pulse oxime-try technology may be compromised by conditions of low tissue perfusion. For comparison purposes the system also enables the independent display of reflectance and transmittance PPG signals simultaneously. Preliminary experiments were performed on volunteers to assess the performance of the probe, where, artificial hypoperfusion was created in individuals and data was recorded with the newly developed trans-reflectance photoplethysmographic mode, and the conventional transmittance and reflectance PPG modes.

  • Published in 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (2009).

Abstract

The acquisition of reliable and meaningful photo-plethysmographic (PPG) signals using conventional pulse oxime-try technology may be compromised by conditions of low tissue perfusion. We have developed a novel 'trans-reflectance' PPG measurement system which combines reflectance and transmit-tance together into a single mode. For comparison purposes the system also enables the independent display of reflectance and transmittance PPG signals simultaneously. Preliminary experiments were performed on volunteers to assess the performance of the probe, where, artificial hypoperfusion was created in individuals and data was recorded with the newly developed trans-reflectance photoplethysmographic mode, and the conventional transmittance and reflectance PPG modes. The PPG signals recorded during hypoperfusion using the trans-reflectance mode were of good quality with higher signal-to-noise ratio than those obtained from the transmittance and reflectance modes.

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Kyriacou BibliographyOther PPG Applications

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG). Method: Method.SetupSignals: PPGSignalsPPGMethodMethod

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Shafique, M., Phillips, J., & Kyriacou, P. (2009). A novel non-invasive trans-reflectance photoplethysmographic probe for use in cases of low peripheral blood perfusion. 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2009.5334165
Shafique, M., J.P. Phillips, and P.A. Kyriacou. 2009. "A novel non-invasive trans-reflectance photoplethysmographic probe for use in cases of low peripheral blood perfusion." 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/iembs.2009.5334165.
Shafique, M., Phillips, J. and Kyriacou, P. (2009) 'A novel non-invasive trans-reflectance photoplethysmographic probe for use in cases of low peripheral blood perfusion', 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. doi: 10.1109/iembs.2009.5334165.
Shafique, M., et al. "A novel non-invasive trans-reflectance photoplethysmographic probe for use in cases of low peripheral blood perfusion." 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2009. https://doi.org/10.1109/iembs.2009.5334165.
M. Shafique, J. Phillips, and P. Kyriacou, "A novel non-invasive trans-reflectance photoplethysmographic probe for use in cases of low peripheral blood perfusion," 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2009, doi: 10.1109/iembs.2009.5334165.
@inproceedings{shafique2009novel,
  title         = {{A novel non-invasive trans-reflectance photoplethysmographic probe for use in cases of low peripheral blood perfusion}},
  author        = {Shafique, M. and Phillips, J.P. and Kyriacou, P.A.},
  year          = {2009},
  booktitle     = {2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society},
  doi           = {10.1109/iembs.2009.5334165}
}

Added to the ChatPPG research hub