Paperdoi:10.1109/iembs.2010.5627730
Evaluation of a multimode photoplethysmographic sensor during cuff-induced hypoperfusion
2010 Annual International Conference of the IEEE Engineering in Medicine and Biology
TL;DR
Photoplethysmography (PPG) is a technique widely used to monitor volumetric blood changes induced by cardiac pulsations. Pulse oximetry uses the technique of PPG to estimate arterial oxygen saturation values(S(p)O(2)). In poorly perfused tissues, S(p)O(2) readings may be compromised due to the poor quality of the PPG signals.
- Published in 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology (2010).
Abstract
Photoplethysmography (PPG) is a technique widely used to monitor volumetric blood changes induced by cardiac pulsations. Pulse oximetry uses the technique of PPG to estimate arterial oxygen saturation values(S(p)O(2)). In poorly perfused tissues, S(p)O(2) readings may be compromised due to the poor quality of the PPG signals. We have developed a new multimode PPG measurement system which utilizes a reflectance PPG probe that operates in reflectance, transmittance and transreflectance mode simultaneously aiming to improve the quality of the PPG signals in cases of poor peripheral perfusion. In order to evaluate the performance of the probe, experiments were performed in healthy volunteers. A blood pressure cuff was used to induce systematic and controlled artificial hypoperfusion while PPG signals were recorded using all three modes. It was found that the amplitude of the transreflectance signal was significantly greater than the other two conventional PPG sensors at all occlusion pressures, suggesting the potential for improved signal acquisition in patients with peripheral hypoperfusion.
Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Signals
Keywords
How it works
Cite this paper
Shafique, M., Phillips, J. P., & Kyriacou, P. A. (2010). Evaluation of a multimode photoplethysmographic sensor during cuff-induced hypoperfusion. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2010.5627730
Shafique, Muhammad, Justin P Phillips, and Panayiotis A Kyriacou. 2010. "Evaluation of a multimode photoplethysmographic sensor during cuff-induced hypoperfusion." 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. https://doi.org/10.1109/iembs.2010.5627730.
Shafique, M., Phillips, J. P. and Kyriacou, P. A. (2010) 'Evaluation of a multimode photoplethysmographic sensor during cuff-induced hypoperfusion', 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology. doi: 10.1109/iembs.2010.5627730.
Shafique, Muhammad, et al. "Evaluation of a multimode photoplethysmographic sensor during cuff-induced hypoperfusion." 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, 2010. https://doi.org/10.1109/iembs.2010.5627730.
M. Shafique, J. P. Phillips, and P. A. Kyriacou, "Evaluation of a multimode photoplethysmographic sensor during cuff-induced hypoperfusion," 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, 2010, doi: 10.1109/iembs.2010.5627730.
@inproceedings{shafique2010evaluation,
title = {{Evaluation of a multimode photoplethysmographic sensor during cuff-induced hypoperfusion}},
author = {Shafique, Muhammad and Phillips, Justin P. and Kyriacou, Panayiotis A.},
year = {2010},
booktitle = {2010 Annual International Conference of the IEEE Engineering in Medicine and Biology},
doi = {10.1109/iembs.2010.5627730}
}Added to the ChatPPG research hub