Paperdoi:10.83056/mmu.32483298
Wearable multi-wavelength photoplethysmography deep learning heart rate estimation (MMU thesis)
Manchester Metropolitan University e-space, 2026-05-28 (thesis/report)
TL;DR
Wrist multi-wavelength PPG (blue, green, red, IR) for HR. Introduces a dataset of 26,442 samples from 20 participants, Fitzpatrick I–VI, varied HR and motion types, and an uncertainty-aware deep-learning HR estimator with sensor fusion, evaluated LOSO. Blue+green+red+IR was the best combination.
- Form factor: wrist
Abstract
Wrist-worn photoplethysmography (PPG) has become a popular method for continuous and remote heart rate monitoring, but single-wavelength PPG faces limitations in accuracy, robustness, and generalisability. This study explores multi-wavelength PPG sensing to enhance heart rate estimation accuracy, robustness, and fairness across diverse populations, particularly for healthcare applications. A novel dataset comprising 26,442 samples from 20 participants with diverse skin types (Fitzpatrick I-VI) and varying heart rates and motion types was introduced, including blue, green, red, and infrared PPG wavelengths. Additionally, an uncertaintyaware deep learning method was developed for wrist-worn PPG heart rate estimation, optimised for single- and multi-wavelength PPG, using sensor fusion and LOSO crossvalidation. The pilot study analysed the impact of skin melanin, biological sex, and wavelength on PPG heart rate estimation. The blue-green-red-IR combination proved most effective. Significant differences in error distributions across wavelengths were observed for skin melanin and biological sex. High melanin content was associated with higher MAE (8.4 ± 2.1 BPM) compared to low melanin (6.1 ± 2.2 BPM). An uncertainty-aware postprocessing method demonstrated competitive performance, mitigating the effects of skin melanin content by equalising the MAE to 3.3 ± 0.9 BPM for high melanin and 3.3 ± 1.3 BPM for low melanin. The method recorded lowest MAE values on three existing single-wavelength datasets—1.3 ± 0.6 BPM on IEEE Train, 1.2 ± 0.4 BPM on BAMI 2, and 2.5 ± 0.9 BPM on PPG DaLiA-compared to existing deep learning methods. For the newly collected multi-wavelength dataset, the method achieved a MAE of 3.3 ± 1.1 BPM. The pilot study improved reliability through selective rejection of uncertain samples, despite lower retention rates. By investigating multi-wavelength PPG and introducing reliability indicators, this research aims to enhance accuracy and reliability of wristworn PPG heart rate monitoring across diverse populations, addressing disparities and improving healthcare applicability. These findings lay groundwork for further research advancing more inclusive and reliable wrist-worn PPG heart rate estimation methods.
Verbatim from DataCite (opens in a new tab) · Licence: https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
APA
Ray, D. (2026). Wearable multi-wavelength photoplethysmography deep learning heart rate estimation (MMU thesis). Manchester Metropolitan University e-space, 2026-05-28. https://doi.org/10.83056/mmu.32483298
BibTeX
@article{ray2026wearable,
title = {{Wearable multi-wavelength photoplethysmography deep learning heart rate estimation (MMU thesis)}},
author = {Ray, Daniel},
year = {2026},
journal = {Manchester Metropolitan University e-space, 2026-05-28},
doi = {10.83056/mmu.32483298}
}Built from the hub record. Check it against the publisher before submitting.