TL;DR
Noninvasive continuous blood pressure measurements are desirable for patients and clinicians. This work proposes and validates a method for transmural pressure measurement using photoplethysmography (PPG) in an in vitro setup that allows control of pressure and flow conditions. The optimum pulsatile volume measure is obtained by comparing parameters extracted from the photoplethysmographic signal (AC amplitude, normalized pulse volume (NPV) and adjusted pulse volume (APV)).
- Published in Physiological Measurement (2016).
Abstract
Noninvasive continuous blood pressure measurements are desirable for patients and clinicians. This work proposes and validates a method for transmural pressure measurement using photoplethysmography (PPG) in an in vitro setup that allows control of pressure and flow conditions. The optimum pulsatile volume measure is obtained by comparing parameters extracted from the photoplethysmographic signal (AC amplitude, normalized pulse volume (NPV) and adjusted pulse volume (APV)). Pulsatile volume can then provide pressure measurements using the exponential pressure–volume ( P–V ) relationship and validated using the gold standard catheter pressure measurement. Pressure, red (R) and infrared (IR) PPG signals were recorded continuously in two arterial models with different cross-sectional areas (Model 1 and Model 2) utilising a pulsatile pump. Flow rates were controlled by varying pumping frequencies at low and high stroke volumes. The optimum method for estimation of the pulsatile volume is through APV, which had a highly significant correlation ( r 2 = 0.99, p r 2 = 0.98, p IR ( r 2 = 0.73, z = 25.85, p R ( r 2 = 0.95, z = 12.26, p AC ( r 2 = 0.52, z = 28.29, p AC ( r 2 = 0.92, z = 15.27, p IR ( r 2 = 0.92, z = 10.23, p R ( r 2 = 0.96, z = 5.08, p AC ( r 2 = 0.63, z = 22.47, p AC ( r 2 = 0.92, z = 17.70, p < 0.0001) in Model 2. These preliminary findings suggest that APV could be used as a potential non-invasive continuous method of blood pressure measurement at different flow conditions.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://publishingsupport.iopscience.iop.org/iop-standard/v1
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Signals
Keywords
How it works
Cite this paper
Njoum, H., & Kyriacou, P. A. (2016). Photoplethysmography for an independent measure of pulsatile pressure under controlled flow conditions. Physiological Measurement. https://doi.org/10.1088/1361-6579/38/2/87
Njoum, Haneen and Panayiotis A Kyriacou. 2016. "Photoplethysmography for an independent measure of pulsatile pressure under controlled flow conditions." Physiological Measurement. https://doi.org/10.1088/1361-6579/38/2/87.
Njoum, H. and Kyriacou, P. A. (2016) 'Photoplethysmography for an independent measure of pulsatile pressure under controlled flow conditions', Physiological Measurement. doi: 10.1088/1361-6579/38/2/87.
Njoum, Haneen, and Panayiotis A Kyriacou "Photoplethysmography for an independent measure of pulsatile pressure under controlled flow conditions." Physiological Measurement, 2016. https://doi.org/10.1088/1361-6579/38/2/87.
H. Njoum and P. A. Kyriacou, "Photoplethysmography for an independent measure of pulsatile pressure under controlled flow conditions," Physiological Measurement, 2016, doi: 10.1088/1361-6579/38/2/87.
@article{njoum2016photoplethysmography,
title = {{Photoplethysmography for an independent measure of pulsatile pressure under controlled flow conditions}},
author = {Njoum, Haneen and Kyriacou, Panayiotis A.},
year = {2016},
journal = {Physiological Measurement},
doi = {10.1088/1361-6579/38/2/87}
}Added to the ChatPPG research hub