PaperarXiv:2412.17538
Robust Heart Rate Detection via Multi-Site Photoplethysmography
arXiv preprint (eess.SP) · Accepted at EMBC2024
Open code
TL;DR
Smartwatches have become popular for monitoring physiological parameters outside clinical settings. Using reflective photoplethysmography (PPG) sensors, such watches can non-invasively estimate heart rate (HR) in everyday environments and throughout a patient's day. However, achieving consistently high accuracy remains challenging, particularly during moments of increased motion or due to varying device placement.
- Form factor: wrist
Abstract
Smartwatches have become popular for monitoring physiological parameters outside clinical settings. Using reflective photoplethysmography (PPG) sensors, such watches can non-invasively estimate heart rate (HR) in everyday environments and throughout a patient's day. However, achieving consistently high accuracy remains challenging, particularly during moments of increased motion or due to varying device placement. In this paper, we introduce a novel sensor fusion method for estimating HR that flexibly combines samples from multiple PPG sensors placed across the patient's body, including wrist, ankle, head, and sternum (chest). Our method first estimates signal quality across all inputs to dynamically integrate them into a joint and robust PPG signal for HR estimation. We evaluate our method on a novel dataset of PPG and ECG recordings from 14 participants who engaged in real-world activities outside the laboratory over the course of a whole day. Our method achieves a mean HR error of 2.4 bpm, which is 46% lower than the mean error of the best-performing single device (4.4 bpm, head).
Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
Cite this paper
APA
Meier, M., & Holz, C. (2024). Robust Heart Rate Detection via Multi-Site Photoplethysmography. arXiv preprint · Accepted at EMBC2024. https://doi.org/10.48550/arXiv.2412.17538
BibTeX
@misc{meier2024robust,
title = {{Robust Heart Rate Detection via Multi-Site Photoplethysmography}},
author = {Meier, Manuel and Holz, Christian},
year = {2024},
howpublished = {arXiv preprint · Accepted at EMBC2024},
doi = {10.48550/arXiv.2412.17538},
eprint = {2412.17538},
archivePrefix = {arXiv}
}Built from the hub record. Check it against the publisher before submitting.
Record updated
Added to the ChatPPG research hub