Paperdoi:10.1109/embc.2019.8856662

The Sensing Endotracheal Tube

Venue listed2019Added Nov 5, 2026

  • JM
  • JP
  • SS
  • PK

Authors: James May, Justin Phillips, Saowrat Snidvongs, Panayiotis Kyriacou

2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)

TL;DR

Current pulse oximetry sensors are not very well suited to use in anaesthetised patients as it has been shown that during episodes of reduced peripheral circulation they do not function correctly or fail all together [1], [2]. To address this problem a new design for a photoplethysmography (PPG) endotracheal (ET) sensor to monitor pulse rate and oxygen saturation (SpO2) internally is presented. Flexible printed circuit board (PCB) technology and miniature optoelectronic components have been implemented and integrated with a custom instrumentation system [3].

  • Published in 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (2019).
  • DOI 10.1109/embc.2019.8856662.

Abstract

Current pulse oximetry sensors are not very well suited to use in anaesthetised patients as it has been shown that during episodes of reduced peripheral circulation they do not function correctly or fail all together [1], [2]. To address this problem a new design for a photoplethysmography (PPG) endotracheal (ET) sensor to monitor pulse rate and oxygen saturation (SpO2) internally is presented. Flexible printed circuit board (PCB) technology and miniature optoelectronic components have been implemented and integrated with a custom instrumentation system [3]. The sensor adheres and conforms to the curvature of standard french-gauge 7 and 8 ET tubes at the point just above the inflatable cuff within the laryngeal positioning markings. A 3D-modelled, optically clear, soft silicon encapsulation electronically and thermally isolates the electronic components whilst providing a smooth surface to aid the insertion on the ET tube during standard intubation procedures. A pilot study with 5 patients (3 Female, 2 Male), undergoing abdominal and limb laproscopic procedures has demonstrated the operation of the sensing ET tube, showing good quality red and infra-red PPG signals. Preliminary signal analysis reveals heart rate can be measured via PPG successfully, with saturation (SpO2) readings in close agreement with the commercial monitors of 97.9 % (STD 0.2 %) and 98.6 % (STD 0.8 %) respectively.

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Keywords

Kyriacou BibliographyOrgan Tissue Perfusion

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

May, J., Phillips, J., Snidvongs, S., & Kyriacou, P. (2019). The Sensing Endotracheal Tube. 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2019.8856662
May, James, Justin Phillips, Saowrat Snidvongs, and Panayiotis Kyriacou. 2019. "The Sensing Endotracheal Tube." 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2019.8856662.
May, J., Phillips, J., Snidvongs, S. and Kyriacou, P. (2019) 'The Sensing Endotracheal Tube', 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society. doi: 10.1109/embc.2019.8856662.
May, James, et al. "The Sensing Endotracheal Tube." 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2019. https://doi.org/10.1109/embc.2019.8856662.
J. May, J. Phillips, S. Snidvongs, and P. Kyriacou, "The Sensing Endotracheal Tube," 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2019, doi: 10.1109/embc.2019.8856662.
@inproceedings{may2019sensing,
  title         = {{The Sensing Endotracheal Tube}},
  author        = {May, James and Phillips, Justin and Snidvongs, Saowrat and Kyriacou, Panayiotis},
  year          = {2019},
  booktitle     = {2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society},
  doi           = {10.1109/embc.2019.8856662}
}

Added to the ChatPPG research hub