Paperdoi:10.1109/embc.2013.6609853
Evaluation of a combined reflectance photoplethysmography and laser Doppler flowmetry surface probe
2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
TL;DR
This study presents evaluation of a system combining laser Doppler flowmetry and photoplethysmography (PPG) in a single probe for the simultaneous measurement of perfusion and blood flow in the finger. A cuff sphygmomanometer was used to partially occlude the arteries supplying the hand to investigate the effect of low pressure on photoplethysmographic and laser Doppler signals and also on calculated arterial blood oxygen saturation values (SpO2). Red and infrared PPG and Doppler signals were recorded from six healthy volunteers at various pressures.
- Published in 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (2013).
Abstract
This study presents evaluation of a system combining laser Doppler flowmetry and photoplethysmography (PPG) in a single probe for the simultaneous measurement of perfusion and blood flow in the finger. A cuff sphygmomanometer was used to partially occlude the arteries supplying the hand to investigate the effect of low pressure on photoplethysmographic and laser Doppler signals and also on calculated arterial blood oxygen saturation values (SpO2). Red and infrared PPG and Doppler signals were recorded from six healthy volunteers at various pressures. Good quality signals were recorded in all subjects at low cuff pressures; however both PPG and Doppler signals showed a gradual decrease in amplitude at higher pressures. SpO2 values calculated from the PPG signals showed higher deviation from measurements made on the contralateral hand using a commercial pulse oximeter at higher cuff pressures.
Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Signals
Keywords
How it works
Cite this paper
Abdollahi, Z., Phillips, J. P., & Kyriacou, P. A. (2013). Evaluation of a combined reflectance photoplethysmography and laser Doppler flowmetry surface probe. 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2013.6609853
Abdollahi, Zahra, Justin P. Phillips, and Panayiotis A. Kyriacou. 2013. "Evaluation of a combined reflectance photoplethysmography and laser Doppler flowmetry surface probe." 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2013.6609853.
Abdollahi, Z., Phillips, J. P. and Kyriacou, P. A. (2013) 'Evaluation of a combined reflectance photoplethysmography and laser Doppler flowmetry surface probe', 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. doi: 10.1109/embc.2013.6609853.
Abdollahi, Zahra, et al. "Evaluation of a combined reflectance photoplethysmography and laser Doppler flowmetry surface probe." 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2013. https://doi.org/10.1109/embc.2013.6609853.
Z. Abdollahi, J. P. Phillips, and P. A. Kyriacou, "Evaluation of a combined reflectance photoplethysmography and laser Doppler flowmetry surface probe," 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2013, doi: 10.1109/embc.2013.6609853.
@inproceedings{abdollahi2013evaluation,
title = {{Evaluation of a combined reflectance photoplethysmography and laser Doppler flowmetry surface probe}},
author = {Abdollahi, Zahra and Phillips, Justin P. and Kyriacou, Panayiotis A.},
year = {2013},
booktitle = {2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society},
doi = {10.1109/embc.2013.6609853}