Paperdoi:10.1109/tbme.2015.2417863
Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion
IEEE Transactions on Biomedical Engineering
TL;DR
In the last decades, photoplethysmography (PPG) has been used as a noninvasive technique for monitoring arterial oxygen saturation by pulse oximetry (PO), whereas near-infrared spectroscopy (NIRS) has been employed for monitoring tissue blood perfusion. While NIRS offers more parameters to evaluate oxygen delivery and consumption in deep tissues, PO only assesses the state of oxygen delivery. For a broader assessment of blood perfusion, this paper explores the utilization of dual-wavelength PPG by using the pulsatile (ac) and continuous (dc) PPG for the estimation of arterial oxygen saturation (SpO2) by conventional PO.
- Published in IEEE Transactions on Biomedical Engineering (2015).
Abstract
In the last decades, photoplethysmography (PPG) has been used as a noninvasive technique for monitoring arterial oxygen saturation by pulse oximetry (PO), whereas near-infrared spectroscopy (NIRS) has been employed for monitoring tissue blood perfusion. While NIRS offers more parameters to evaluate oxygen delivery and consumption in deep tissues, PO only assesses the state of oxygen delivery. For a broader assessment of blood perfusion, this paper explores the utilization of dual-wavelength PPG by using the pulsatile (ac) and continuous (dc) PPG for the estimation of arterial oxygen saturation (SpO2) by conventional PO. Additionally, the Beer-Lambert law is applied to the dc components only for the estimation of changes in deoxyhemoglobin (HHb), oxyhemoglobin (HbO2), and total hemoglobin (tHb) as in NIRS. The system was evaluated on the forearm of 21 healthy volunteers during induction of venous occlusion (VO) and total occlusion (TO). A reflectance PPG probe and NIRS sensor were applied above the brachioradialis, PO sensors were applied on the fingers, and all the signals were acquired simultaneously. While NIRS and forearm SpO2 indicated VO, SpO2 from the finger did not exhibit any significant drop from baseline. During TO, all the indexes indicated the change in blood perfusion. HHb, HbO2, and tHb changes estimated by PPG presented high correlation with the same parameters obtained by NIRS during VO (r(2) = 0.960, r(2) = 0.821, and r(2) = 0.974, respectively) and during TO (r(2) = 0.988, r(2) = 0.940, and r(2) = 0.938, respectively). The system demonstrated the ability to extract valuable information from PPG signals for a broader assessment of tissue blood perfusion.
Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Signals
Keywords
How it works
Cite this paper
Abay, T. Y., & Kyriacou, P. A. (2015). Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2015.2417863
Abay, Tomas Ysehak and Panayiotis A. Kyriacou. 2015. "Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion." IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2015.2417863.
Abay, T. Y. and Kyriacou, P. A. (2015) 'Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion', IEEE Transactions on Biomedical Engineering. doi: 10.1109/tbme.2015.2417863.
Abay, Tomas Ysehak, and Panayiotis A. Kyriacou "Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion." IEEE Transactions on Biomedical Engineering, 2015. https://doi.org/10.1109/tbme.2015.2417863.
T. Y. Abay and P. A. Kyriacou, "Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion," IEEE Transactions on Biomedical Engineering, 2015, doi: 10.1109/tbme.2015.2417863.
@article{abay2015reflectance,
title = {{Reflectance Photoplethysmography as Noninvasive Monitoring of Tissue Blood Perfusion}},
author = {Abay, Tomas Ysehak and Kyriacou, Panayiotis A.},
year = {2015},
journal = {IEEE Transactions on Biomedical Engineering},
doi = {10.1109/tbme.2015.2417863}
}Added to the ChatPPG research hub