Photoplethysmography (PPG) is a noninvasive optical technique, which can also be used to derive important parameters other than arterial oxygen saturation (SpO2). In this work, the accuracy of the technique on detecting changes in blood perfusion during different levels of vascular occlusions has been explored. A dual-wavelength, reflectance PPG probe was applied on the left forearm of 10 healthy volunteers and raw PPG signals were acquired by a research PPG processing system.

  • Published in 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (2015).

Abstract

Photoplethysmography (PPG) is a noninvasive optical technique, which can also be used to derive important parameters other than arterial oxygen saturation (SpO2). In this work, the accuracy of the technique on detecting changes in blood perfusion during different levels of vascular occlusions has been explored. A dual-wavelength, reflectance PPG probe was applied on the left forearm of 10 healthy volunteers and raw PPG signals were acquired by a research PPG processing system. The raw PPG signals were separated into pulsatile AC and continuous DC PPG components. The signals were used to estimate SpO2 and changes in concentration of oxygenated, deoxygenated, and total haemoglobin. Different levels of occlusions, from 20 mmHg to total occlusion were induced by a pressure-cuff on the left arm. The system was able to indicate all the occlusions. In particular, the haemoglobin concentration changes estimated from PPG were in high agreement with Near Infrared Spectroscopy measurements.

Verbatim from Europe PMC (opens in a new tab) · Abstract via Europe PMC; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Signals

Keywords

Kyriacou BibliographyOther PPG Applications

How it works

How Method works: Setup → Method → TargetSetup: Signals (PPG). Method: Method.SetupSignals: PPGSignalsPPGMethodMethod

Cite this paper

Cite this paper with the fields recorded here. Check it against the publisher before submitting.

Abay, T. Y., & Kyriacou, P. A. (2015). Accuracy of reflectance photoplethysmography on detecting cuff-induced vascular occlusions. 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2015.7318498
Abay, T. Y. and P. A. Kyriacou. 2015. "Accuracy of reflectance photoplethysmography on detecting cuff-induced vascular occlusions." 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. https://doi.org/10.1109/embc.2015.7318498.
Abay, T. Y. and Kyriacou, P. A. (2015) 'Accuracy of reflectance photoplethysmography on detecting cuff-induced vascular occlusions', 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. doi: 10.1109/embc.2015.7318498.
Abay, T. Y., and P. A. Kyriacou "Accuracy of reflectance photoplethysmography on detecting cuff-induced vascular occlusions." 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2015. https://doi.org/10.1109/embc.2015.7318498.
T. Y. Abay and P. A. Kyriacou, "Accuracy of reflectance photoplethysmography on detecting cuff-induced vascular occlusions," 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2015, doi: 10.1109/embc.2015.7318498.
@inproceedings{abay2015accuracy,
  title         = {{Accuracy of reflectance photoplethysmography on detecting cuff-induced vascular occlusions}},
  author        = {Abay, T. Y. and Kyriacou, P. A.},
  year          = {2015},
  booktitle     = {2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society},
  doi           = {10.1109/embc.2015.7318498}
}

Added to the ChatPPG research hub