FDA 510(k) · Masimo

K250757: Radius VSM and Accessories (Masimo Corporation)

Masimo Corporation received FDA 510(k) K250757 for Radius VSM and Accessories, with a decision date of May 29, 2025 (substantially equivalent).

Prescription or OTC: Unknown (no FDA document we parsed states it).

FDA record for K250757FDA summary or statement (PDF)

FDA facts

Official fields for K250757
FDA numberK250757
Pathway510(k)
ApplicantMasimo Corporation
Device nameRadius VSM and Accessories
Product codeMHX: Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
Regulation (21 CFR)870.1025
Device classClass 2
Date receivedMar 12, 2025
Decision dateMay 29, 2025
DecisionSubstantially Equivalent (SESE)
510(k) typeTraditional

Source: openFDA device 510(k) data, data through Oct 26, 2026.

Indications for use parsed from FDA documents

? Radius VSM: The Radius VSM and accessories are intended to be used as both a wearable multi-parameter patient monitor and an accessory to a multi-parameter patient monitor that is intended for multi-parameter physiological patient monitoring in hospital and healthcare facilities. The Radius VSM and accessories are indicated for the monitoring of hemodynamic (including ECG, arrhythmia detection, non-invasive blood pressure, Sp02, Pulse Rate, PVi, heart rate, and temperature), and respiratory (e.g., impedance, acoustic, and pleth-based respiration rate) physiological parameters along with the orientation and activity of adults. The Radius VSM and accessories are indicated for the non-invasive continuous monitoring of functional oxygen saturation of arterial hemoglobin (Sp02) and Pulse Rate (PR) of well or poorly perfused adults during both no motion and motion conditions. The Radius VSM and accessories are indicated for continuous monitoring of skin temperature of adults. The Radius VSM and accessories are indicated for monitoring of the orientation and activity of patients including those susceptible to pressure ulcers. The Radius VSM and accessories are indicated for the continuous non-invasive monitoring of PVi as a measure of relative variability of the photoplethysmograph (pleth) of adults during no motion conditions. PVi may be used as a noninvasive dynamic indicator of fluid responsiveness in select populations of mechanically ventilated adult patients. Accuracy of PVi in predicting fluid responsiveness is variable and influenced by numerous patient, procedure and device related factors. PVi measures the variation in the plethysmography amplitude but does not provide measurements of stroke volume or cardiac output. Fluid management decisions should be based on a

Extracted automatically from FDA's 510(k) summary. It can contain extraction errors and is not a verified quote. Read the wording in the FDA PDF before relying on it.

Predicates parsed from FDA documents

FDA numbers found next to the word "predicate" in the summary. The list can include reference devices; check the PDF for which device is the primary predicate.

Later records that cite K250757

  • K260676 Radius VSM and Accessories (Masimo, Oct 14, 2026, MHX)

ChatPPG interpretation

A 510(k) decision of "substantially equivalent" means FDA found the device as safe and effective as a legally marketed predicate. FDA's word for this is cleared, not approved. The clearance covers the device and indications in this submission; it does not extend to other features or versions of the same product that were not part of it. See FDA cleared vs approved.

Product code MHX is "Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)", class 2, 21 CFR 870.1025.

Our labels for filtering: claim Remote / vital-sign monitoring, sensor Other. These are heuristics, not FDA fields.