Paperdoi:10.1364/BOE.560022
Speckle contrast optical spectroscopy for cuffless blood pressure estimation based on microvascular blood flow and volume oscillations
Biomedical Optics Express 16(8):3004, 2025
TL;DR
High-speed (390 Hz) speckle contrast optical spectroscopy recorded blood flow and blood volume waveforms at two wavelengths on the wrist and finger. Feeding flow plus volume features into subject-specific machine-learning models estimated systolic and diastolic blood pressure with errors of about 2.9 and 2.1 mmHg (SD) across a wide BP range, a 31 % improvement in systolic estimation over PPG alone, and the gain held when people were re-measured weeks later.
- Form factor: wrist
Abstract
This work introduces high-speed (390 Hz) speckle contrast optical spectroscopy (SCOS) to enable simultaneous measurements of multi-anatomic site microvascular blood volume and flow oscillations. Simultaneous blood flow and volume waveforms were extracted at two wavelengths on the wrist and finger, in reflectance and transmission mode, respectively. Blood volume changes (also known as photoplethysmography, or PPG) were determined based on intensity oscillations. Blood flow information was determined based on dynamic light scattering information encoded in the 2D spatial speckle pattern after removal of stochastic and instrument noise. We extracted a wide array of temporal, shape-based, and frequency-domain features from each high-resolution waveform, as well as features that characterize the temporal relationships between these features. These features and their inter-relationships are determined by the dynamic biomechanical properties of peripheral microvasculature, including vascular compliance and resistance, which are key determinants of dynamic changes in systemic blood pressure (BP). In comparison to PPG alone, SCOS demonstrated a notable 31% improvement (p = 3.45 * 10 −7 ) in systolic BP estimation when integrated into subject-specific machine-learning models. The resulting errors were remarkably low (systolic BP: 0.06+/- 2.88 mmHg, diastolic BP: 0.09 +/-2.14 mmHg) across a wide range of BP variations (range SBP: 89–284 mmHg). This improvement was sustained several weeks later within a re-measured cohort, indicating highly robust BP predictions. Looking ahead, high-speed SCOS holds the potential to substantially enhance the non-invasive characterization of the cardiovascular system, including continuous and non-invasive BP measurements, which are a long-sought-after goal of the biomedical community.
Verbatim from the publisher's DOI record (opens in a new tab) · Publisher licence: https://doi.org/10.1364/OA_License_v2#VOR-OA
Results on ChatPPG leaderboards
All leaderboardsNo results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.
Tasks & signals
Tasks
Signals
Keywords
How it works
- Wavelengths
- 532 nm, 808 nm
Cite this paper
Garrett, A., Kim, B., Gurel, N. Z., Sie, E. J., Wilson, B. K., Marsili, F., Forman, J. P., Hamburg, N. M., Boas, D. A., & Roblyer, D. M. (2025). Speckle contrast optical spectroscopy for cuffless blood pressure estimation based on microvascular blood flow and volume oscillations. Biomedical Optics Express , 2025, 16(8), 3004. https://doi.org/10.1364/BOE.560022
Garrett, Ariane, Byungchan Kim, Nil Z. Gurel, Edbert Jarvis Sie, Benjamin K. Wilson, Francesco Marsili, John P. Forman, Naomi M. Hamburg, David A. Boas, and Darren M. Roblyer. 2025. "Speckle contrast optical spectroscopy for cuffless blood pressure estimation based on microvascular blood flow and volume oscillations." Biomedical Optics Express , 2025 16 (8): 3004. https://doi.org/10.1364/BOE.560022.
Garrett, A., Kim, B., Gurel, N. Z., Sie, E. J., Wilson, B. K., Marsili, F., Forman, J. P., Hamburg, N. M., Boas, D. A. and Roblyer, D. M. (2025) 'Speckle contrast optical spectroscopy for cuffless blood pressure estimation based on microvascular blood flow and volume oscillations', Biomedical Optics Express , 2025, 16(8), p. 3004. doi: 10.1364/BOE.560022.
Garrett, Ariane, et al. "Speckle contrast optical spectroscopy for cuffless blood pressure estimation based on microvascular blood flow and volume oscillations." Biomedical Optics Express , 2025, vol. 16, no. 8, 2025, p. 3004. https://doi.org/10.1364/BOE.560022.
A. Garrett et al., "Speckle contrast optical spectroscopy for cuffless blood pressure estimation based on microvascular blood flow and volume oscillations," Biomedical Optics Express , 2025, vol. 16, no. 8, p. 3004, 2025, doi: 10.1364/BOE.560022.
@article{garrett2025speckle,
title = {{Speckle contrast optical spectroscopy for cuffless blood pressure estimation based on microvascular blood flow and volume oscillations}},
author = {Garrett, Ariane and Kim, Byungchan and Gurel, Nil Z. and Sie, Edbert Jarvis and Wilson, Benjamin K. and Marsili, Francesco and Forman, John P. and Hamburg, Naomi M. and Boas, David A. and Roblyer, Darren M.},
year = {2025},
journal = {Biomedical Optics Express , 2025},
volume = {16},
number = {8},
pages = {3004},
doi = {10.1364/BOE.560022}
}Added to the ChatPPG research hub