Paperdoi:10.1145/3795866.3844457

VasTrack: anchoring nocturnal drift for physics-informed blood pressure monitoring (MobiCom '26)

Venue listed2026Added Oct 26, 2026

  • ZZ
  • HH
  • CY
  • HL
  • HM
  • XH
  • Z
  • HC
  • +1

Authors: Zixin Zheng, He Hao, C S Yue, Haozhen Lin, Huadóng Ma, Xiaotong Hou, Zhongtao Du, Hao Zhen Cui, Anfu Zhou (names as listed by OpenAlex)

MobiCom '26 (32nd Annual Int. Conf. on Mobile Computing and Networking), pp. 818–832

Licence: CC BY-NC-ND 4.0

TL;DR

A retrospective analysis of a 1,328-patient ICU dataset shows a pronounced day–night domain gap: vascular state drifts in a personalised, non-stationary way during sleep, so cuffless models calibrated in the daytime make large errors at night. VasTrack is a mmWave wearable with an Anchor-and-Track design:

  • Form factor: wearable (mmWave radar; body site not stated in abstract)

Abstract

Nocturnal blood pressure (BP) is a stronger predictor of cardiovascular risk than daytime measurements, yet its unobtrusive monitoring remains a formidable challenge. For practical convenience, existing cuffless methods typically rely on daytime calibration. However, through a retrospective analysis of a 1,328-patient ICU dataset, we reveal a pronounced day-night domain gap: vascular states undergo highly personalized, non-stationary drifts during sleep. Consequently, conventional daytime calibrations fail to capture nocturnal hemodynamic shifts, leading to substantial measurement errors. To address this, we propose VasTrack, a mmWave wearable system that bridges the day-night gap via a novel “Anchor-and-Track” architecture. Specifically, to establish a vascular anchor, we design a full-spectrum pressure scan method to extract the user's intrinsic vascular compliance during a standard cuff measurement, serving as a personalized biomechanical prior for nocturnal BP tracking. To track nocturnal vascular dynamics, our multi-granular tracking network transforms temporal signals into 2D phase-aligned physiological manifolds. It then employs biomechanical-based rhythmic gating to dynamically compensate for vascular tone variations using cardiopulmonary rhythms as proxies. Evaluation on 43 participants spanning healthy individuals and clinical patients over 340 hours shows that VasTrack achieves a mean error and standard deviation of 0.24±7.31 mmHg for systolic blood pressure and 0.10±4.87 mmHg for diastolic blood pressure. It also captures acute BP fluctuations exceeding 30 mmHg and a preliminary six-month evaluation suggests feasibility for extended monitoring periods, offering a potential pathway toward long-term cardiovascular health management.

Verbatim from Semantic Scholar (opens in a new tab) · Abstract via Semantic Scholar; © the authors/publisher

Results on ChatPPG leaderboards

All leaderboards

No results from this paper on ChatPPG leaderboards yet. Browse the leaderboards.

Tasks & signals

Tasks

Blood pressure

Keywords

cuffless BPnocturnal BPdippingday-night domain gapcalibration driftmmWavephysics-informedcuff anchorMobiCom

How it works

How Method works: Setup → Method → TargetSetup: Signals (mmWave radar (wearable), cuff (calibration anchor)); Form factor (wearable (mmWave radar; body site not stated in abstract)). Method: Method. Target: Blood pressure.SetupSignals: mmWave radar (wearable), cuff (calibration anchor)SignalsmmWave radar (wearable), cuff…Form factor: wearable (mmWave radar; body site not stated in abstract)Form factorwearable (mmWave radar; body site not…MethodMethodTargetBlood pressureBlood pressure

Cite this paper

APA

Zheng, Z., Hao, H., Yue, C. S., Lin, H., Ma, H., Hou, X., Du, Z., Cui, H. Z., & Zhou, A. (2026). VasTrack: anchoring nocturnal drift for physics-informed blood pressure monitoring (MobiCom '26). MobiCom '26 , pp. 818–832. https://doi.org/10.1145/3795866.3844457

BibTeX

@article{zheng2026vastrack,
  title         = {{VasTrack: anchoring nocturnal drift for physics-informed blood pressure monitoring (MobiCom '26)}},
  author        = {Zheng, Zixin and Hao, He and Yue, C. S. and Lin, Haozhen and Ma, Huadóng and Hou, Xiaotong and Du, Zhongtao and Cui, Hao Zhen and Zhou, Anfu},
  year          = {2026},
  journal       = {MobiCom '26 , pp. 818–832},
  doi           = {10.1145/3795866.3844457}
}

Built from the hub record. Check it against the publisher before submitting.

Added to the ChatPPG research hub