PaperarXiv:2610.23727

ECG-SDI: Single-lead Electrocardiogram Enables Continuous Sleep Depth Index Profiling and Scalable Digital Biomarkers for Sleep Health

Preprint2026Added Oct 19, 2026

  • DX
  • QZ
  • SZ
  • HW
  • JW
  • YZ
  • TP
  • SH

Authors: Donglin Xie, Qingshuo Zhao, Songchi Zhou, Haoyu Wang, Jingyu Wang, Yuxi Zhou, Thomas Penzel, Shenda Hong

arXiv 2610.23727v1 (eess.SP), submitted 2026-10-16, announced 2026-10-19

Open code

TL;DR

No summary in the hub record yet.

  • Form factor: other

Abstract

Conventional sleep staging provides a coarse-grained representation that obscures within-stage depth variation. We developed ECG-SDI, a single-lead electrocardiography (ECG) framework for continuous sleep-depth profiling and digital biomarker extraction. Using 12,392 overnight polysomnographic recordings, we trained and validated a two-stage deep learning model supervised by conventional sleep-stage labels. Correlations with ordered stages excluding rapid eye movement (REM) sleep were 0.828 in the pooled internal test set and 0.848 in the external Cleveland Family Study; corresponding REM classification AUROCs were 0.954 and 0.977. Overnight trajectories captured within-stage variation. Biomarker-based phenotyping identified a disturbed subtype associated with poorer subjective sleep quality and higher all-cause mortality in the Sleep Heart Health Study (adjusted hazard ratio, 1.20; 95% CI, 1.05-1.38). Among 507 participants with paired recordings before and after continuous positive airway pressure (CPAP), normalized sleep-depth area increased by 6.1% and shallow-sleep burden below 0.3 decreased by 16.0%. Exploratory analyses linked reductions in approximate entropy and depth variability to reduced oxygen desaturation and increased sleep efficiency, respectively (Spearman rho = 0.24 and 0.12); both associations remained positive after covariate adjustment. Mean ECG-SDI within N2 increased by 0.017 (95% CI, 0.004-0.030). A wearable proof-of-concept illustrated the acquisition-to-report workflow. These findings support ECG-based sleep phenotyping and further evaluation of CPAP response monitoring at home.

Verbatim from arXiv (opens in a new tab) · arXiv metadata (abstracts are released under CC0)

Results on ChatPPG leaderboards · 2

All leaderboards
LeaderboardMethodResultRank
Cleveland Family Study (CFS) AUROCSleep stagingECG-SDI0.977AUROC, higher is better#1 of 1
SHHS, NSRR AUROCSleep stagingECG-SDI0.908AUROC, higher is better#1 of 1

2 rows are credited to this paper. Ranks apply within each leaderboard only, as reported by the source.

Tasks & signals

Signals

Keywords

sleepsleep-depthsingle-lead-ECGREMcontinuous-indexranking-lossdigital-biomarkersCPAPOSAmortalityNSRRPeking-UniversityCharite

Datasets

How it works

How ECG-SDI works: Setup → Method → TargetSetup: Signals (ecg); Form factor (other). Method: ECG-SDI. Target: Sleep staging.SetupSignals: ecgSignalsecgForm factor: otherForm factorotherMethodECG-SDITargetSleep stagingSleep staging

Cite this paper

APA

Xie, D., Zhao, Q., Zhou, S., Wang, H., Wang, J., Zhou, Y., Penzel, T., & Hong, S. (2026). ECG-SDI: Single-lead Electrocardiogram Enables Continuous Sleep Depth Index Profiling and Scalable Digital Biomarkers for Sleep Health. arXiv 2610.23727v1 , submitted 2026-10-16, announced 2026-10-19. https://arxiv.org/abs/2610.23727

BibTeX

@misc{xie2026ecgsdi,
  title         = {{ECG-SDI: Single-lead Electrocardiogram Enables Continuous Sleep Depth Index Profiling and Scalable Digital Biomarkers for Sleep Health}},
  author        = {Xie, Donglin and Zhao, Qingshuo and Zhou, Songchi and Wang, Haoyu and Wang, Jingyu and Zhou, Yuxi and Penzel, Thomas and Hong, Shenda},
  year          = {2026},
  howpublished  = {arXiv 2610.23727v1 , submitted 2026-10-16, announced 2026-10-19},
  eprint        = {2610.23727},
  archivePrefix = {arXiv}
}

Built from the hub record. Check it against the publisher before submitting.

Added to the ChatPPG research hub